Bucher Hydraulics SDVPSA-3... serie size 5 trykkbegrensningsventil - Sandwich med bypass funksjon

Bucher Hydraulics trykkventiler
  • With cartridge valve, type DVPSA-3D…-10…
  • Interface to ISO 4401-05-04
  • 5 pressure ranges available
  • External pilot-oil drain
  • Very stable operation
  • External cartridge parts are zinc plated and chromited (CrVI-free)
  • Sandwich body is zinc-phosphated
  • The slip-on coil can be rotated, and it can be replaced without opening the hydraulic envelope
  • Various plug connections and voltages are available
       
Kontakt Hydex vedrørende Bucher Hydraulics SDVPSA-3... serie trykkbegrensningsventil

Type        Proportional Pressure Relief Valve, Size 5
Designation Proportional pressure relief valve
Design Sandwich design, seated pilot, spool-type main stage
Mounting method Stack mounting
Size Size 05 interface to ISO 4401-05-04 / DIN 24 340 A10
Interface
Max operating pressure 315 bar
Max flow rate 120 l/min
Flow direction See symbols
Hydraulic fluid HL and HLP hydraulic oils to DIN 51 524, for other fluids please contact BHFRU
Hydraulic fluid
temperature range
- 25°C ... + 70 °C
Viscosity range 15...380 mm²/s (cSt), recommended 20 ... 130 mm²/s (cSt)
Minimum fluid cleanliness 18/16/13 to ISO 4406 : 1999
For mer informasjon  Datablad --- Oversikt

Kontakt Hydex vedrørende Bucher Hydraulics SDDB... serie trykkbegrensningsventil 
  
 
Page rendered: 29.12.2022 03:26:45
OXX.Authorization.User.Username: Hydex_Systemhydraulikk_anonym (NO)