Type |
|
Bypass Hydrostat Cartridge, Size 10 mm |
|
|
Design |
|
Seated pilot stage, sliding spool main stage |
|
|
Mounting method |
|
Screw−in cartridge M42x1,5 |
|
|
Size |
|
Nominal 10 mm, cavity type DD |
|
|
Cavity type thread |
|
|
|
|
Max operating pressure |
|
315 bar in A and B (and Z) |
|
|
Max flow rate 1 ⇒ 2 |
|
140 l/min |
|
|
Max flow rate attainable at the actuator |
|
... 55 l/min with DWPA-2 (Δp 8 bar) ... 45 l/min with DWPZ-2 (Δp 5 bar) |
|
|
Flow direction |
|
A ⇒ B (see symbol) |
|
|
Hydraulic fluid |
|
Hydraulic oils HL and HLP to DIN 51 524; other fluids by arrangement |
|
|
Hydraulic fluid temperature range |
|
−25°C ... + 60 °C |
|
|
Viscosity range |
|
10...300 mm²/s (cSt) |
|
|
Minimum fluid cleanliness |
|
18/15 to ISO 4406 / CETOP RP70H 8 ... 9 to NAS 1638 |
|
|
For mer informasjon |
|
Datablad --- Oversikt |
|
|