Type |
|
Electrically Operated Pressure−Reducing Cartridge, Size 16 |
|
|
Designation |
|
Pressure−reducing cartridge for 2 electrically selectable reduced pressures |
|
|
Design |
|
Seated pilot stage, spool−type main stage with external pilot oil drain to 3 |
|
|
Mounting method |
|
Screw−in cartridge M42 x 2 |
|
|
Size |
|
Nominal size 16 cavity type EB to ISO 7789−42−06−0−07 |
|
|
Cavity type thread |
|
EB M42x2 |
|
|
Max operating pressure |
|
350 bar in ports 1, 2 |
|
|
Max flow rate |
|
250 l/min |
|
|
Flow direction |
|
2 → 1 (see symbols) |
|
|
Hydraulic fluid |
|
Hydraulic oils HL and HLP to DIN 51 524; for other fluids, please consult BUCHER |
|
|
Hydraulic fluid temperature range |
|
−25 °C ... + 80 °C |
|
|
Viscosity range |
|
10...500 mm²/s (cSt), reommended 15...250 mm²/s (cSt) |
|
|
Minimum fluid cleanliness |
|
20/18/15 to ISO 4406 : 1999 |
|
|
For mer informasjon |
|
Klikk her --- Oversikt |
|
|