Type |
|
Controller and valve amplifier |
|
|
Use |
|
Proportional valves with two magnets |
|
Supply voltage |
|
24V DC (22...28 V DC) |
|
PWM (valve current) |
|
9.7kHz with fast de-excitation and short-circuit monitoring |
|
Inputs |
|
6, opto-decoupled, of which 1 x Enable, 1 x Ramp OFF and 4 x Setpoint (internal) |
|
Output |
|
1 x 24V/100mA |
|
Dither generator |
|
Selectable 50 to 150Hz, amplitude 0 to 10%, referred to the current selected |
|
Measuring sockets |
|
The valve current for the A and B magnets can be measured at 1V/A on the two measuring sockets |
|
Temperature range |
|
-20°C...+60°C |
|
Sensor modules |
|
+/–10V, 12mA +/–8mA, 4–20mA 0–10V, 7.5V +/–4V Change of sign for the controller outputs, the sensor inputs and the setpoint-sensor output |
|
For mer informasjon |
|
Klikk her --- Datablad |
|