Type |
|
Digital controller |
|
|
Use |
|
Actuation of servo and proportional valves |
|
Supply voltage |
|
24V DC, nominal (22...28V) DC |
|
Inputs |
|
6, opto-decoupled, of which 1 x Enable, 1 x Ramp OFF and 4 x setpoint (internal) |
|
Alarm output |
|
1 x 24V/100mA - The inputs may possibly be differently used. |
|
Measuring sockets |
|
The output signal of ±10V can be measured at full deflection on Measuring Sockets M1 and M2 This signal is equivalent to ±20mA or 12mA ±8mA |
|
Temperature range |
|
–20°C to +60°C |
|
Controller setting range |
|
1 to 32000 for P, I, DT1 |
|
Sensor modules |
|
±10V, 12mA ±8mA, 4–20mA, 0–10V, 7.5V ±4V |
|
For mer informasjon |
|
Klikk her --- Datablad |
|