Bucher Hydraulics RVSAE 3/6... serie tilbakeslagsventil

Bucher Hydraulics tilbakeslagsventiler
  • High pressure rating
  • Virtually zero leakage
  • Compact construction
  • Same valve body for 3000 psi and 6000 psi
  • Same valve body for check directions A-to-B and B-to-A
  • Optional orifice-bleed in check direction
  • Optional orifice for metered flow in the no-flow direction
       
Kontakt Hydex vedrørende Bucher Hydraulics RVSAE 3/6... serie tilbakeslagsventil

Type        Check Valves for SAE Flange Ports
Designation SAE check valve
Design Guided spherical-poppet design
Mounting method Fits between port and flange
Size For SAE ¾“ to 2“ flange ports
Max operating pressure 420 bar
Max flow rate 1000 l/min
No-flow direction Reversible by inverting the valve (see symbols)
Hydraulic fluid HL and HLP hydraulic oils to DIN 51 524, Other fluids, contact Bucher Hydraulics
Hydraulic fluid
temperature range
- 30°C ... + 80 °C
Viscosity range 10...500 mm²/s (cSt)
Minimum fluid cleanliness 18/14 to ISO 4406 / CETOP RP70H 8 ... 9 to NAS 1638